Dispatch Received — Unit E11
Burnaby Fire Department
🔥
Structure Fire — Commercial
Working Fire
--:--
INC-2026-04001
Burnaby Centre — Unit 4
4242 Kingsway Ave, Burnaby BC
Construction
Type II-B
Storeys
2
Sprinklers
✓ Full
Year Built
1987
FDC
North Face
Knox Box
East Entry
⚠️
Hazmat — Diesel Fuel P1
~500L storage tank — Generator room, P1 south wall — ER Guide #128
🧱
Asbestos Caution — Pre-1990
Built 1987. Ceiling tiles and pipe insulation may contain ACM. Do not disturb. Full PPE required.
Key Locations
FDC — North Face
Knox — East Entry
H1 Kingsway — 20m
H2 Nelson — 25m
Gas — South Rear
FACP — Lobby East
⌂ Home
Working Fire
INC-2026-04001
Burnaby Centre — Unit 4
E11
--:--:--
BUILDING INFORMATION
Burnaby Centre — Unit 4
4242 Kingsway Ave, Burnaby BC
Occupancy Type
Commercial / Retail Mixed Use
Construction
Type II-B Concrete
Stories
2 Above Grade
Year Built
1987
Ground Floor
Retail Units A & B
Second Floor
Office / Meeting Rooms
Asbestos Warning — Pre-1990 Construction
Building constructed 1987. Ceiling tiles, pipe insulation, and floor tiles may contain asbestos. Use appropriate PPE. Do not disturb ceiling materials during operations.
Building Contacts
Property Manager
John Smith
Burnaby Centre Properties
604-555-0123
Superintendent
Maria Garcia
On-site weekdays 08:00-17:00
604-555-0456
Tactical Data
FDC Location
North face — Kingsway Ave side
Gas Shutoff
South face — rear parking area
FACP Location
Main lobby — east wall inside entry
Knox Box
Main entry — east face right of doors
Sprinkler System
Type
Wet Pipe — Full Coverage
Both floors + parking level
Last Inspection
January 2025
Annual — passed all tests
Sprinkler Contractor
Pacific Fire Protection
604-555-0789
Fire Department Connection
FDC North
North face — Kingsway Ave side, ground level
2.5" Siamese, feeds sprinkler + standpipe combined
Supply Pressure
150 PSI minimum
Alarm System
Panel
Edwards EST3
Addressable, 8 zones
Monitoring
Paladin Security
24/7 central station
Annunciator
Main lobby — east wall beside entry
Hazardous Material On Site
Diesel Fuel — Parking Level P1
Material
Diesel Fuel No. 2
Quantity
~500L Storage Tank
Location
Generator room, P1 south wall
ER Guide
#128 — Flammable Liquids
Building Conditions
Asbestos — Pre-1990 Construction
Building constructed 1987. Ceiling tiles, pipe insulation, and floor tiles may contain asbestos-containing materials (ACM). Do not disturb. Full PPE required for any ceiling or wall breach.
Service Contractors
Elevator
KONE Elevators
604-555-1111
Sprinkler / Fire Protection
Pacific Fire Protection
604-555-0789
HVAC
Ainsworth
604-555-2222
Electrical
Houle Electric
604-555-3333
First Alarm Response
Engine E11 — North face FDC. Establish water supply from H1 Kingsway. Pump FDC at 150 PSI.
Ladder L22 — Kingsway Ave (south) side. Aerial to roof if needed. Ventilation assignment.
Second Alarm
Additional engine to south hydrant H2. Backup supply line. RIT standby.
Tactical Notes
Type II-B concrete construction — good fire containment between floors. Retail occupancy = high civilian traffic during business hours (09:00–21:00). Roof access via north stairwell only. Check for homeless occupants after hours. Parking level diesel hazmat — keep crews above unless P1 involved.
ERG Guide #128 — Diesel / Fuel Oil
Flammable Liquid
Isolation Distances
Initial Isolation
30 metres all directions
Large Spill Evacuation
300 metres downwind
Fire Involvement
800 metres if tank BLEVE risk
Emergency Contacts
BFD Dispatch
Burnaby Fire Department
911
BC Hydro
Power Emergency
1-800-BC HYDRO
FortisBC Gas
Gas Emergency
1-800-663-9911
CANUTEC
Hazmat 24hr
1-888-226-8832
BFD Symbol Legend
How to Use ARGUS Respond
1. Use left sidebar to navigate sections — tap any button
2. Drawings tab shows site plan and floor plans — pan and zoom
3. Tap symbols on the floor plan for detailed info
4. Check Hazards first on arrival — red cards = critical
5. Tap any phone number to call directly
ARGUS Support
Contact
Ladder 22 Inc.
jake@ladder22.ca